热门搜索:
YW/0-5m液位变送器鸿泰产品测量准确
YW/0-5m液位变送器鸿泰产品测量准确
型号":"YW/0-5m","输出信号":"4~20mA","工作电压":"24VDC","测量范围":"0~5.0m","精度等级":"0.5"
型号":"YW/0-5m","输出信号":"4~20mA","工作电压":"24VDC","测量范围":"0~5.0m","精度等级":"0.5"
型号":"YW/0-5m","输出信号":"4~20mA","工作电压":"24VDC","测量范围":"0~5.0m","精度等级":"0.5"
隔离温度变送器 | 50.00 | 个 | {"型号":"WS9060/900-1400℃","输入信号":"热电偶信号","输出信号":"4~20mA","工作电压":"24VDC±10%","测量范围":"900~1400℃","精度等级":"±0.2%F.S","较高工作温度":"1400℃","特殊需求":"DIN T型导轨安装"} | |
温度变送器 | 30.00 | 个 | {"型号":"MSC304-10C0","输入信号":"热电阻信号","输出信号":"4~20mA","工作电压":"24VDC±10%","测量范围":"0~300℃","精度等级":"±0.2%F.S","较高工作温度":"300℃","特殊需求":"DIN T型导轨安装"} | |
液位变送器 | 3.00 | 个 | {"型号":"FL-YW5m","输入信号":"介质变化","输出信号":"4~20mA","工作电压":"24VDC","测量范围":"0~5m","精度等级":"0.5","尺寸规格":"探头长度5m","较高工作温度":"≤70℃","生产厂家":"无","参照标准":"JB/T 7340-2007","备注":"1.使用寿命:≥3年;2.验收标准:2.1不同厂家设备型号不一致,技术参数必须一致;2.2不满足上述技术要求时退换货处理."} | |
**压力变送器 | 4.00 | 台 | {"型号":"PDS423H/1FS1/A1DA/G61/G81/-0.1~0MPa","测量范围":"-0.1~0MPa","精度等级":"0.1","接口规格":"M20*1.5","输出信号":"4~20mA","额定电压":"24VDCV","防爆防护等级":"IP65"} | |
隔膜压力变送器 | 4.00 | 台 | {"型号":"DN50/0~1.6MPa","测量范围":"0~1.6MPa","精度等级":"0.1","接口规格":"DN50PN4.0MPa","输出信号":"4~20mA","额定电压":"24VDCV","防爆防护等级":"IP65","参照标准":"GB/T 28474.1-2012"} | |
液位变送器 | 10.00 | 个 | {"型号":"YW/0-5m","输出信号":"4~20mA","工作电压":"24VDC","测量范围":"0~5.0m","精度等级":"0.5"} | |
液位变送器 | 1.00 | 个 | {"型号":"FL-YW10m","输入信号":"介质变化","输出信号":"4~20mA","工作电压":"24DCV","测量范围":"0~10m","精度等级":"0.1m","尺寸规格":"145mm*28mm","较高工作温度":"85℃","生产厂家":"不限定","参照标准":"GB/T 25477-2010","备注":"要求:\n防腐线长大于12m\n材质:传感器不锈钢304,接线端铸铝,接口防水\n验收标准:\n1)包装完好,内部备件无破碎、损坏。\n2)需保证备件十成新,上电后功能正常。\n3)元件若有升级,出具升级前后元件的外观、尺寸、性能等方面的差异,需提供明一份。\n4)如不符合验收标准,退换货或。"} | |
液位变送器 | 6.00 | 个 | {"型号":"W0~6M/4~20mA/24VDC/0.5级","输入信号":"介质变化","输出信号":"4~20mA","工作电压":"24VDC","测量范围":"0~6m","精度等级":"0.5级","尺寸规格":"探头长度6m","较高工作温度":"≤70℃","生产厂家":"无","参照标准":"JB/T 7340-2007","备注":"1.使用寿命:≥3年;2.验收标准:到货应附带合格及材质.产品出现质量问题,现场安装尺寸不符厂家要及时无条件更换或退货,若未达到使用寿命供货厂家必须给予赔付,所产生费用由供货商承担,如因质量问题造成公司经济损失的,按照公司相关规定进行处罚。3、不同厂家设备型号不一致,但技术参数必须一致。"} | |
水位计 | 3.00 | 块 | {"型号":"DWY-Ⅲ-19QZ","输入输出信号":"电源: 220VAC±5% ;自带4~20mADC模拟量信号输出;6路报警输出,无源常开触点(220V/100mA),可在线任意设定,自动记忆","测量范围":"0、±15mm、±30mm、±50mm、±75mm、±100mm、±150mm、±200mm、±225mm、±250mm","尺寸规格":"160*80*145mm(高*宽*长)","配件尺寸规格":"19点位由25针母头输入接口连接,自带引线≥3m及点位标识","工作压力":"大气压力","工作温度":"-10~+45℃","生产厂家":"原设备厂家为宁波市鄞州大嵩锅炉仪表厂","材质":"外壳材质:铁,内置电子元器件","特殊要求":"仪表具有一个或两个报警点信号误发屏蔽其他报警点信号的功能(例如:高三值报警点误发,不会导致高一值和高二值报警点误发)","参照标准":"DL/T 1393-2014","备注":"二次仪表显示为光柱形式,液相部分为绿色,汽相部分为红色,同时具备数码显示功能,直观显示水位;安装方式:盘装式;进口/国产:国产;使用寿命:4年;\n验收标准:\n1、设备型号一致,设备性能不能满足生产需求,退货;\n2、由于产品升级或停产导致设备型号不一致,设备性能、盘装尺寸满足生产需求,办理入库;\n3、外观破损、变形、受潮、附件缺件,退货。"} | |
电磁流量计 | 1.00 | 台 | {"型号":"DN125","测量范围":"0~100m3/h","精度等级":"1","输出信号":"4~20mA","额定电压":"220V","本地显示":"一体式显示","工艺接口规格":"DN125","工作温度":"80℃","测量介质":"水","防爆防护等级":"IP65","国内/国外":"国内"} | |
智能气体检测变送器 | 25.00 | 个 | {"型号":"QB2000N","输入信号":"可燃性气体","输出信号":"4~20mA","工作电压":"24VDC","测量范围":"0~**LEL","精度等级":"±5%","尺寸规格":"长约160mm宽约140mm高约85mm","较高工作温度":"180℃","生产厂家":"不限","参照标准":"GB 50493-2009","备注":"使用要求:检测天然气体使用,采用催化燃烧式传感器,防爆外壳,坚固耐用,高可靠和准确性。良好的抗干扰性能。验收标准:到货物资需满足技术要求,为全新备件,若为升级产品需满足现场安装需求且不影响使用寿命,精度,并提供升级明,不满足使用要求给予处理"} | |
隔膜压力变送器 | 4.00 | 块 | {"型号":"PDS473H/1EH2KB/CA03/A1DA/G61/G51/S01/0-6.3Mpa","测量范围":"0~6.3MPa","精度等级":"0.5","接口规格":"法兰环面连接DN50PN100(3米长毛细管)","输出信号":"4~20(HART)mA","额定电压":"DC24V","防爆防护等级":"IP65","参照标准":"GB/T 28474.1-2012"} | |
浮子式流量计 | 10.00 | 个 | {"规格型号":"TZ37","测量范围":"0~0.4L/min","耐压范围":"0~1MPa","测量温度范围":"0~80℃","工艺接口规格":"M14*1.5","流量计材质":"**玻璃","测量介质":"水","生产厂家":"不*生产厂家","参照标准":"JB/T 9255-2015","备注":"验货标准:\n1、由于产品升级或停产导致设备型号不一致,但接口尺寸、安装方式等参数满足技术要求,设备厂家出明,入库.\n2、外观破损、变形、附件缺件,退货.\n3、使用寿命:1年."} | |
双金属温度计 | 4.00 | 个 | {"测量范围":"0~100℃","精度等级":"1.5","插入长度":"100mm","温杆直径":"ф6mm","表盘直径":"ф100mm","接口规格":"M16*1.5","安装形式":"螺纹安装","型号":"WSS-481/200*100","主要材质":"不锈钢304","特殊要求":"万向表头","参照标准":"JB/T 8803-2015"} | |
液位变送器 | 50.00 | 个 | {"型号":"FL-YW12m","输入信号":"介质变化","输出信号":"4~20mA","工作电压":"24DVC","测量范围":"0~12m","精度等级":"0.1m","尺寸规格":"145mm*28mm","较高工作温度":"85℃","生产厂家":"不限定","参照标准":"GB/T 25477-2010","备注":"要求:\n防腐线长大于12m\n材质:传感器不锈钢304,接线端铸铝,接口防水\n使用寿命:≥1年\n验收标准:\n1)包装完好,内部备件无破碎、损坏。\n2)需保证备件十成新,上电后功能正常。\n3)元件若有升级,出具升级前后元件的外观、尺寸、性能等方面的差异,需提供明一份。\n4)如不符合验收标准,退换货或。"} |